HLFL-2000 Fiber Laser Chiller for High-Power Laser Cutting and Precision CNC Machine Tool Cooling

CE
RoHS
REACH
ISO 9001

The HLFL-2000 Fiber Laser Chiller is a high-performance thermal management solution specifically engineered to address the heat dissipation challenges of multi-kilowatt laser systems. In high-precision industrial manufacturing, excessive thermal drift can lead to laser beam misalignment and significant material waste. The HLFL-2000 solves this by providing a robust 7KW cooling capacity with a dual-circuit cooling system, ensuring both the laser source and optics remain at their ideal temperatures. Manufactured to meet international ISO Standard guidelines, this unit features a 3HP compressor and an 18-liter tank to stabilize extreme thermal loads. As a flagship product from Chiller Industrial, it integrates smart diagnostics and high-lift pumps to maintain consistent flow across complex manufacturing environments.

HLFL-2000 Fiber Laser Chiller

HLFL-2000 Fiber Laser Chiller

Dual Temp System
7KW Cooling
3HP Power
重要な申請のヒント:

The HLFL-2000 utilizes a high-lift 42m pump. Always ensure the water loop is fully primed and air-purged before the first start-up to prevent cavitation and protect the 480W pump motor.

製品紹介

The HLFL-2000 Fiber Laser Chiller provides robust and reliable cooling performance for high-power lasers, CNC machine tools, and other demanding industrial equipment. Designed for high performance and extreme durability, this chiller features advanced dual-temperature control circuits that independently manage the laser source and the optical components. Its robust construction and 18-liter tank capacity ensure consistently high cooling efficiency, making it ideal for large-scale factories, workshops, and intensive manufacturing environments where 24/7 uptime is critical.

製品仕様

Parameter Specification
モデル HLFL-2000 (3000 Series Platform)
電圧/周波数 AC 220-240V / 50Hz
コンプレッサーの出力 4100W
冷却能力 3HP / 7KW ±5%
温度安定性 ±0.5℃ (Dual Temp Control)
Electric Heating Power 400W + 1800W (Dual System)
Pump Lift / Flow Max Lift: 42m | Rated Flow: 70L/min
タンク容量 18 Liters
Water Outlets Chilled & Normal Temp φ10 Quick Connectors
Dimensions 740 × 550 × 960 mm (L×W×H)

製品の特徴

Dual Temperature Control

Dual Cooling System for Fiber Lasers

The HLFL-2000 features an intelligent dual-path cooling design. This allows the system to simultaneously provide chilled water for the laser source and normal-temperature water for the optical lens. This synchronized cooling significantly reduces condensation risks and extends the lifespan of sensitive fiber laser components.

産業用安全保護具

Advanced Safety & Diagnostics

Safety is integrated into the core electronics, featuring dual flow alarms, high/low temperature alerts, and compressor overload protection. Following international **[ISO Standard](https://www.iso.org/standard/72393.html)** safety protocols, the HLFL-2000 also includes sensor failure diagnostics to prevent hardware damage before it occurs.

商品詳細

  • Refrigerant: Optimized for R410a/R22 high-efficiency heat exchange.
  • Construction: Heavy-duty steel frame with industrial-grade casters.
  • Quick Connectors: Dual φ10 connectors for rapid deployment.
  • Pump: Powerful 480W motor capable of a 42m max head.

オプション品

  • Customized voltage configurations (3-Phase 380V available).
  • Enhanced heater kits for sub-zero climate operation.
  • Remote monitoring and alarm output communication ports.
  • Customizable plumbing sizes for specific CNC interfaces.

Technical Operation

Ventilation Distance: To maintain the rated 7KW cooling capacity, ensure the chiller’s air outlet is at least 1.5 meters away from obstacles. Side air inlets require a clearance of at least 0.5 meters to ensure sufficient airflow for the high-power condenser.

Product Working Principle: The HLFL-2000 utilizes a closed-loop refrigeration cycle. The compressor drives refrigerant through an evaporator where it absorbs heat from the circulating water. The dual-path system then distributes the cooled water at two different temperature setpoints, while heat is dissipated through the forced-air condenser.

FAQ

Q: Is the HLFL-2000 suitable for 3000W lasers?
A: While based on the 3000 series platform, it is optimized for 2000W-3000W fiber lasers. For higher loads, please check our full catalog at **[Chiller Industrial](https://chillerbath.com/)**.

Q: Why does it have two heating powers (400W + 1800W)?
A: The dual system allows for independent temperature stabilization in cold environments, ensuring both the laser head and laser source reach operating temperature quickly.

Q: What maintenance is required?
A: Clean the dust filters weekly and replace the deionized water every 3 months to ensure the 42m lift pump remains at peak performance.